31 research outputs found

    Real-world evidence supporting Tandem Control-IQ hybrid closed-loop success in the Medicare and Medicaid type 1 and type 2 diabetes populations

    Get PDF
    BACKGROUND: The Tandem Control-IQ (CIQ) system has demonstrated significant glycemic improvements in large randomized controlled and real-world trials. Use of this system is lower in people with type 1 diabetes (T1D) government-sponsored insurance and those with type 2 diabetes (T2D). This analysis aimed to evaluate the performance of CIQ in these groups. METHODS AND MATERIALS: A retrospective analysis of CIQ users was performed. Users age ≥6 years with a t:slim X2 Pump and >30 days of continuous glucose monitoring (CGM) data pre-CIQ and >30 days post-CIQ technology initiation were included. RESULTS: A total of 4243 Medicare and 1332 Medicaid CIQ users were analyzed among whom 5075 had T1D and 500 had T2D. After starting CIQ, the Medicare beneficiaries group saw significant improvement in time in target range 70–180 mg/dL (TIR; 64% vs. 74%; P < 0.0001), glucose management index (GMI; 7.3% vs. 7.0%; P < 0.0001), and the percentage of users meeting American Diabetes Association (ADA) CGM Glucometrics Guidelines (12.8% vs. 26.3%; P < 0.0001). The Medicaid group also saw significant improvement in TIR (46% vs. 60%; P < 0.0001), GMI (7.9% vs. 7.5%; P < 0.0001), and percentage meeting ADA guidelines (5.7% vs. 13.4%; P < 0.0001). Patients with T2D and either insurance saw significant glycemic improvements. CONCLUSIONS: The CIQ system was effective in the Medicare and Medicaid groups in improving glycemic control. The T2D subgroup also demonstrated improved glycemic control with CIQ use. Glucometrics achieved in this analysis are comparable with those seen in previous randomized controlled clinical trials with the CIQ system

    Optimizing postprandial glucose management in adults with insulin-requiring diabetes: Report and recommendations

    Get PDF
    Faster-acting insulins, new noninsulin drug classes, more flexible insulin-delivery systems, and improved continuous glucose monitoring devices offer unprecedented opportunities to improve postprandial glucose (PPG) management and overall care for adults with insulin-treated diabetes. These developments led the Endocrine Society to convene a working panel of diabetes experts in December 2018 to assess the current state of PPG management, identify innovative ways to improve self-management and quality of life, and align best practices to current and emerging treatment and monitoring options. Drawing on current research and collective clinical experience, we considered the following issues for the ∼200 million adults worldwide with type 1 and insulin-requiring type 2 diabetes: (i) the role of PPG management in reducing the risk of diabetes complications; (ii) barriers preventing effective PPG management; (iii) strategies to reduce PPG excursions and improve patient quality of life; and (iv) education and clinical tools to support endocrinologists in improving PPG management. We concluded that managing PPG to minimize or prevent diabetes-related complications will require elucidating fundamental questions about optimal ways to quantify and clinically assess the metabolic dysregulation and consequences of the abnormal postprandial state in diabetes and recommend research strategies to address these questions. We also identified practical strategies and tools that are already available to reduce barriers to effective PPG management, optimize use of new and emerging clinical tools, and improve patient self-management and quality of life

    Lost in translation: A disconnect between the science and Medicare coverage criteria for continuous subcutaneous insulin infusion

    Get PDF
    Numerous studies have demonstrated the clinical value and safety of insulin pump therapy in type 1 diabetes and type 2 diabetes populations. However, the eligibility criteria for insulin pump coverage required by the Centers for Medicare & Medicaid Services (CMS) discount conclusive evidence that supports insulin pump use in diabetes populations that are currently deemed ineligible. This article discusses the limitations and inconsistencies of the insulin pump eligibility criteria relative to current scientific evidence and proposes workable solutions to address this issue and improve the safety and care of all individuals with diabetes

    A Practical Approach to Using Trend Arrows on the Dexcom G5 CGM System for the Management of Adults With Diabetes

    No full text
    After reviewing previously published methods, we developed a practical approach to adjusting insulin doses based on insulin sensitivity for adult patients with diabetes using rtCGM trend arrow data

    What’s wrong with this picture? A critical review of current Centers for Medicare & Medicaid Services coverage criteria for continuous glucose monitoring

    Get PDF
    Numerous studies have demonstrated the clinical value of continuous glucose monitoring (CGM) in type 1 diabetes and type 2 diabetes populations. However, the eligibility criteria for CGM coverage required by the Centers for Medicare & Medicaid Services (CMS) ignore conclusive evidence that supports CGM use in various diabetes populations that are currently deemed ineligible. This article discusses the limitations and inconsistencies of the CMS eligibility criteria relative to current scientific evidence and proposes workable solutions to address this issue and improve the safety and care of all individuals with diabetes

    Diet‐induced Alzheimer's‐like syndrome in the rabbit

    No full text
    Abstract Introduction Although mouse models of Alzheimer's disease (AD) have increased our understanding of the molecular basis of the disease, none of those models represent late‐onset Alzheimer's Disease which accounts for >90% of AD cases, and no therapeutics developed in the mouse (with the possible exceptions of aduhelm/aducanumab and gantenerumab) have succeeded in preventing or reversing the disease. This technology has allowed much progress in understanding the molecular basis of AD. To further enhance our understanding, we used wild‐type rabbit (with a nearly identical amino acid sequence for amyloid as in humans) to model LOAD by stressing risk factors including age, hypercholesterolemia, and elevated blood glucose levels (BGLs), upon an ε3‐like isoform of apolipoprotein. We report a combined behavioral, imaging, and metabolic study using rabbit as a non‐transgenic model to examine effects of AD‐related risk factors on cognition, intrinsic functional connectivity, and magnetic resonance‐based biomarkers of neuropathology. Methods Aging rabbits were fed a diet enriched with either 2% cholesterol or 10% fat/30% fructose. Monthly tests of novel object recognition (NOR) and object location memory (OLM) were administered to track cognitive impairment. Trace eyeblink conditioning (EBC) was administered as a final test of cognitive impairment. Magnetic resonance imaging (MRI) was used to obtain resting state connectivity and quantitative parametric data (R2*). Results Experimental diets induced hypercholesterolemia or elevated BGL. Both experimental diets induced statistically significant impairment of OLM (but not NOR) and altered intrinsic functional connectivity. EBC was more impaired by fat/fructose diet than by cholesterol. Whole brain and regional R2* MRI values were elevated in both experimental diet groups relative to rabbits on the control diet. Discussion We propose that mechanisms underlying LOAD can be assessed by stressing risk factors for inducing AD and that dietary manipulations can be used to assess etiological differences in the pathologies and effectiveness of potential therapeutics against LOAD. In addition, non‐invasive MRI in awake, non‐anesthetized rabbits further increases the translational value of this non‐transgenic model to study AD
    corecore